Cable cutters
- Description:
- • Dip insulation according to IEC 60855-1
• Nominal insulation 36 kV
• For crush-free cutting of copper (Ø 14 mm), steel (Ø 7 mm) and aluminium cables (Ø 14 mm)
• Clean cut thanks to new cutting edge geometry
• Low force required
• Special tool steel - Length (mm):
- 520
- Technical data:
- • Standard: IEC 60855-1
• Test certificate: 1000V GS
• Total length: 520 mm
• Cutting edge length: 20 mm
• Head width: 60 mm
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- Description:
- • Dip insulation according to IEC 60900
• For single- and multi-wire copper and aluminium cables
• With eccentric drive with double bearing
• Virtually break-proof splining
• Separates thin sheet steel casing
• With ratchet function
• Not suitable for hardened steel wire
• Phosphated
• Special tool steel - Width (mm):
- 135
- Height (mm):
- 50
- Length (mm):
- 385
- Technical data:
- With ratchet function
Weight: 942 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Cable diameter: 25 mm (single-wire)
Cable diameter: 52 mm (multi-wire)
Head width D: 135.0 mm
Total length L1: 310.0 mm
Partial length L2: 110.0 mm
Material 1: special steel
Material 2: phosphated
Test certificate: 1000V
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- Description:
- • Dip insulation according to IEC 60900
• With coated head
• For single- and multi-wire copper and aluminium cables
• With adjustable screw joint
• With anti-pinch protection
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• Special tool steel - Width (mm):
- 110
- Height (mm):
- 30
- Length (mm):
- 220
- Technical data:
- VDE
Weight: 280 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Head width D: 31.0 mm
Total length L: 165.0 mm
Material 1: special steel
Material 2: phosphated
Max. diameter: 17.0 mm
Test certificate: 1000V
Cutting edge length S: 20.5 mm
Cutting edge value: 35.0 mm²
Head height (A): 13.0 mm
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- Description:
- • Dip insulation according to IEC 60900
• For single- and multi-wire copper and aluminium cables
• For stranded conductors up to 50 mm²
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Matt chrome-plated
• Special tool steel - Width (mm):
- 110
- Height (mm):
- 30
- Length (mm):
- 205
- Technical data:
- VDE
Weight: 250 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Head width D: 23.5 mm
Total length L: 165.0 mm
Material 1: special steel
Material 2: matt chrome-plated
Max. diameter: 15.0 mm
Test certificate: 1000V
Cutting edge length S: 24.0 mm
Cutting edge value: 50.0 mm²
Head height (A): 10.0 mm
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- Description:
- • Dip insulation according to IEC 60900
• With coated head
• For single- and multi-wire copper and aluminium cables
• With adjustable screw joint
• With anti-pinch protection
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• Special tool steel - Width (mm):
- 175
- Height (mm):
- 30
- Length (mm):
- 190
- Technical data:
- VDE
Weight: 400 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Head width D: 33.5 mm
Total length L: 210.0 mm
Material 1: special steel
Material 2: phosphated
Max. diameter: 20.0 mm
Test certificate: 1000V
Cutting edge length S: 34.0 mm
Cutting edge value: 50.0 mm²
Head height (A): 18.0 mm
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- L (mm):
- 165
- A (mm):
- 10,8
- Description:
- • Sleeve insulation according to IEC 60900
• For stranded conductors up to 50 mm²
• For crush-free cutting of single- and multi-wire copper and aluminium cables
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• With 2-component handles
• Special tool steel - D (mm):
- 24,5
- S (mm):
- 15
- Ø max. (mm):
- 10
- Additional information:
- • Sleeve insulation according to IEC 60900
• For stranded conductors up to 50 mm²
• For crush-free cutting of single- and multi-wire copper and aluminium cables
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• With 2-component handles
• Special tool steel
• Test certificate: 1000V GS
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- L (mm):
- 215
- A (mm):
- 13
- Description:
- • Sleeve insulation according to IEC 60900
• For stranded conductors up to 50 mm²
• For crush-free cutting of single- and multi-wire copper and aluminium cables
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• With 2-component handles
• Special tool steel - D (mm):
- 29
- S (mm):
- 17,5
- Ø max. (mm):
- 12,5
- Additional information:
- • Sleeve insulation according to IEC 60900
• For stranded conductors up to 50 mm²
• For crush-free cutting of single- and multi-wire copper and aluminium cables
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• With 2-component handles
• Special tool steel
• Test certificate: 1000V GS
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- L (mm):
- 245
- A (mm):
- 13,5
- Description:
- • Sleeve insulation according to IEC 60900
• For stranded conductors up to 50 mm²
• For crush-free cutting of single- and multi-wire copper and aluminium cables
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• With 2-component handles
• Special tool steel - D (mm):
- 45
- S (mm):
- 31
- Ø max. (mm):
- 15
- Additional information:
- • Sleeve insulation according to IEC 60900
• For stranded conductors up to 50 mm²
• For crush-free cutting of single- and multi-wire copper and aluminium cables
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Phosphated
• With 2-component handles
• Special tool steel
• Test certificate: 1000V GS
Show more details
- Description:
- • Dip insulation according to IEC 60900
• Only suitable for copper and aluminium wire
• For cutting thin wires and sheets
• Matt chrome-plated
• Special tool steel - Width (mm):
- 110
- Height (mm):
- 30
- Length (mm):
- 210
- Technical data:
- VDE
Weight: 170 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Head width D: 14.0 mm
Total length L: 180.0 mm
Material 1: special steel
Material 2: matt chrome-plated
Test certificate: 1000V
Cutting edge length S: 38.0 mm
Head height (A): 9.0 mm
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- Description:
- • Dip insulation according to IEC 60900
• For single- and multi-wire copper and aluminium cables
• With telescopic handles
• With interchangeable cutter head
• Low force required
• Not suitable for steel wire and hard-drawn copper conductors
• Matt chrome-plated
• Special tool steel - Width (mm):
- 160
- Height (mm):
- 50
- Length (mm):
- 410
- Technical data:
- Replacement cutter head: 7881172234
Telescopic
Weight: 2000 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Head width D: 82.0 mm
Total length L1: 360-520 mm
Partial length L2: 63.0 mm
Material 1: special steel
Material 2: matt chrome-plated
Max. diameter: 31.0 mm
Test certificate: 1000V
Cutting edge length S: 35.0 mm
Cutting edge value: 185.0 mm²
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- Description:
- • Dip insulation according to IEC 60900
• For single- and multi-wire copper and aluminium cables
• Coated head
• Automatic reset thanks to spring return
• Cutting process can be interrupted in any position
• Matt chrome-plated
• Special tool steel - Width (mm):
- 180
- Height (mm):
- 35
- Length (mm):
- 300
- Technical data:
- VDE
Weight: 1000 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Head width D: 80.0 mm
Total length L: 290.0 mm
Material 1: special steel
Material 2: matt chrome-plated
Test certificate: 1000V
Cutting edge length S: 35.0 mm
Head height (A): 40.0 mm
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
- Description:
- • Dip insulation according to IEC 60900
• For single- and multi-wire copper and aluminium cables
• Coated head
• Automatic reset thanks to spring return
• Cutting process can be interrupted in any position
• Matt chrome-plated
• Special tool steel - Width (mm):
- 225
- Height (mm):
- 40
- Length (mm):
- 365
- Technical data:
- VDE
Weight: 1150 g
Dip-insulated handles
Dip insulation according to DIN EN 60900
Head width D: 85.0 mm
Total length L: 310.0 mm
Material 1: special steel
Material 2: matt chrome-plated
Test certificate: 1000V
Cutting edge length S: 40.0 mm
Head height (A): 40.0 mm
Show more details
Special item: cannot be returned or cancelled. Additional shipping costs may be incurred. Delivery time subject to availability from the supplier.
Original spare part numbers are for comparison purposes only. All prices are in $, excl. VAT. Errors reserved. Delivery subject to availability.